Challenge
A failed pressure test following the installation of a new completion in a North Sea oil producer led to the discovery of a 2 l/min. leak. The leak presented the operator with a diffi cult choice: undertake a lengthy troubleshooting process or
pull the completion. Further concern about wash-out damage to completion equipment made a quick solution imperative. Several leak sources were suspected. These included 3 gas lift valve (GLV) dummies and a chemical injection valve dummy. The completion also included a new packer, which had not been set, and a lower-set production packer. A plug at 3,827m limited the possibility of deeper leak points.

Solution
A LeakPoint survey was specifi ed and completed in under 10 hours. This precisely located a leak in the upper GLV dummy, which was retrieved and found to be damaged.

Case benefits

  • Rapid, accurate leak location enabled precise diagnosis and remediation
  • Portable diagnostic system enabled fast mobilisation and deployment
  • Rapid diagnosis avoided risk of completion wash-out damage
  • Customer stated intervention and production savings amounted to millions of dollars

Key capabilities

  • Fast, highly accurate location of single or multiple leaks
  • Locates even complex leaks in A, B & C annuli through tubing
  • Sensitive to a wide range of leak rates: 0.02 to >5,000 l/min.
  • Clear, unambiguous log response
  • Proven effectiveness. Pinpointed leaks in >90% of wells surveyed
  • Confidently select and target the most effective remedial intervention

Results
The LeakPoint survey provided the precise location of a diffi cult-to-pinpoint and potentially expensive leak. The survey also verifi ed the integrity of the other completion components within the well. The failed GLV dummy was replaced, a pressure test was performed and no further leakage was found. The customer stated that LeakPoint technology had helped to avoid lost production, re-completion and further intervention costs, saving the operator millions of dollars.

Typical applications

  • Locating leaks in tubing, casing and completion components
  • Pre-workover diagnostics
  • Post-remediation validation